Application
Insulated conductor is used for laying in electric – installation tubes, under and on plaster installation in dry rooms and in closed installation conduits. Direct laying in cable guides is not permitted. Also applied for internal wiring of distribution and switching boxes equipment.
Construction
● Conductor: Copper, class 1, solid conductors
● Insulation: Polyvinyl chloride PVC
Specification
IEC 60228 Conductors of Insulated Cables
IEC 60227-3 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750 V – Part 3: Non-sheathed Cables for Fixed Wiring
DIN VED 0281-3 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750 V – Part 3: Non-sheathed Cables for Fixed Wiring
Note: We also can produce based on other international standards etc.
Characteristics
● Rated voltage Uo/U: 450/750 V;
● Normal operating temperature: 70˚C.
● Short circuit temperature (5 seconds maximum duration): 160˚C.
● IEC 60227-3 (mark 60227 IEC 01)
● Minimum bending radius:
4D for D < 8mm
5D for 8mm < D < 12mm
6D for D > 12mm
Note: D is overall diameter of cable.
Insulated conductor is used for laying in electric – installation tubes, under and on plaster installation in dry rooms and in closed installation conduits. Direct laying in cable guides is not permitted. Also applied for internal wiring of distribution and switching boxes equipment.
Construction
● Conductor: Copper, class 1, solid conductors
● Insulation: Polyvinyl chloride PVC
Specification
IEC 60228 Conductors of Insulated Cables
IEC 60227-3 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750 V – Part 3: Non-sheathed Cables for Fixed Wiring
DIN VED 0281-3 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750 V – Part 3: Non-sheathed Cables for Fixed Wiring
Note: We also can produce based on other international standards etc.
Characteristics
● Rated voltage Uo/U: 450/750 V;
● Normal operating temperature: 70˚C.
● Short circuit temperature (5 seconds maximum duration): 160˚C.
● IEC 60227-3 (mark 60227 IEC 01)
● Minimum bending radius:
4D for D < 8mm
5D for 8mm < D < 12mm
6D for D > 12mm
Note: D is overall diameter of cable.
Technical Parameter
| Conductor | Insulation Thickness | Overall Diameter | Approx. Weight | Max. D.C. Resistance of Conductor at 20℃ | Allowable Ampacities | ||
| Min. | Max. | ||||||
| mm² | Class of Conductor | mm | mm | mm | kg/km | Ω/km | A |
| 1.5 | 2 | 0.7 | 2.7 | 3.3 | 22 | 12.1 | 18 |
| 2.5 | 2 | 0.8 | 3.3 | 4.0 | 35 | 7.41 | 25 |
| 4 | 2 | 0.8 | 3.8 | 4.6 | 50 | 4.61 | 33 |
| 6 | 2 | 0.8 | 4.3 | 5.2 | 70 | 3.08 | 42 |
| 10 | 2 | 1.0 | 5.6 | 6.7 | 112 | 1.83 | 58 |
| 16 | 2 | 1.0 | 6.4 | 7.8 | 169 | 1.15 | 78 |
| 25 | 2 | 1.2 | 8.1 | 9.7 | 262 | 0.727 | 105 |
| 35 | 2 | 1.2 | 9.0 | 10.9 | 357 | 0.524 | 130 |
| 50 | 2 | 1.4 | 10.6 | 12.8 | 497 | 0.387 | 155 |
| 70 | 2 | 1.4 | 12.1 | 14.6 | 675 | 0.268 | 200 |
| 95 | 2 | 1.6 | 14.1 | 17.1 | 936 | 0.193 | 250 |
| 120 | 2 | 1.6 | 15.6 | 18.8 | 1161 | 0.153 | 290 |
| 150 | 2 | 1.8 | 17.3 | 20.9 | 1444 | 0.124 | 335 |
| 185 | 2 | 2.0 | 19.3 | 23.3 | 1801 | 0.0991 | 390 |
| 240 | 2 | 2.2 | 22.0 | 26.6 | 2354 | 0.0754 | 470 |
| 300 | 2 | 2.4 | 24.5 | 29.6 | 2887 | 0.0601 | 240 |
| 400 | 2 | 2.6 | 27.5 | 33.2 | 3825 | 0.0470 | 635 |
YOU MAY LIKE
Related products
-
PVC Electrical Wire
NMY NYM-J NYM-O Cable 300/500V PVC Insulation PVC sheath Industrial Cable
-
PVC Electrical Wire
10mm2 16mm2 25mm2 Green Yellow Earth Grounding Cable Wire
-
PVC Electrical Wire
0.6/1kV Flame Retardant PVC Insulated Wire for Grounding (GV, TFR-GV)
-
PVC Electrical Wire
Outdoor Weather-proof PVC Insulated Wire OW
-
PVC Electrical Wire
Heat-Resistant PVC Insulated Wire (60227 KS IEC 07) 300/500V HIV
-
PVC Electrical Wire
PVC Insulated Wire (60227 KS IEC 01), 450/750V IV
-
PVC Electrical Wire
H07V-R (BVR)
-
PVC Electrical Wire
H07V-K (RV)