2×6+6awg Voluta Triplex Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 6AWG Voluta #6

Code Word: Voluta

Size AWG (Phase Conductors): 6

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application

Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

6-6-6 Voluta Triplex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

ASTM B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474. 

CONSTRUCTION :
6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

TECHNICAL DATA :
6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

Technical Parameter

Code NameVoluta
Phase Conductor MaterialAAC
Phase Conductor Size (awg)6
Phase Conductor Stranding7
Phase Conductor insulation MaterialXLPE
Phase Conductor Insulation Thickness (mils)45
Bare Neutral Messenger MaterialACSR
Bare Neutral Messenger Size(awg)6
Bare Neutral Messenger Stranding6/1
Bare Neutral Messenger Breaking Strength (Lbs)1190 
Weight Per (Lbs/1000 ft) 118
Ampacity (Amps)85 

 

Scroll to Top