2×4+6awg Scallop Triplex Aluminum Conductor Triplex Overhead Service Drop Cable
Triplex Service Drop Cable 4AWG Scallop #4
Code Word: Scallop
Size AWG (Phase Conductors): 4
Voltage: 600V
Number of cores: Triplex
Package : Export wooden drum & iron wooden drum or as customer require
4-4-6 Scallop Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application
4-4-6 Scallop Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.4-4-6 Scallop Triplex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :
4-4-6 Scallop Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction
Phase Conductor | Solid1350-H19 Series Aluminum Conductor. |
Neutral(Messenger )Conductor | Bare ACSR messenger. |
Insulation | Black Cross Linked Polyethylene (XLP) Insulation. |
TECHNICAL DATA :
4-4-6 Scallop Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data
Rated voltage | V | 600 |
Test voltage | Veff kV/Hz | 4/50 |
Laying temperature | °C | min. -5 |
Operating temperature | °C | -30 ~ +90 |
Conductor temperature | °C | max. +90 |
Short-circuit temperature | °C/s | max. +250 /5 |
Bending radius (min.) | mm | 20 × Ø of cable |
Technical Parameter
| Code Name | Scallop |
| Phase Conductor Material | AAC |
| Phase Conductor Size (awg) | 4 |
| Phase Conductor Stranding | 1 |
| Phase Conductor insulation Material | XLPE |
| Phase Conductor Insulation Thickness (mils) | 45 |
| Bare Neutral Messenger Material | ACSR |
| Bare Neutral Messenger Size(awg) | 6 |
| Bare Neutral Messenger Stranding | 6/1 |
| Bare Neutral Messenger Breaking Strength (Lbs) | 1110 |
| Weight Per (Lbs/1000 ft) | 146 |
| Ampacity (Amps) | 115 |
YOU MAY LIKE
Related products
-
Triplex Overhead Service Drop Cable
2×1/0+1/0awg Gammarus Aluminum Conductor Triplex Overhead Service Drop Cable Wire
-
Triplex Overhead Service Drop Cable
2×1/0+2awg Janthina Aluminum Conductor Triplex Overhead Service Drop Cable Wire
-
Triplex Overhead Service Drop Cable
2×2+2awg Clam Aluminum Conductor Triplex Overhead Service Drop Cable Wire
-
Triplex Overhead Service Drop Cable
2×2+2awg Shrimp Aluminum Conductor Triplex Overhead Service Drop Cable Wire
-
Triplex Overhead Service Drop Cable
2×4+4awg Prawn Aluminum Conductor Triplex Overhead Service Drop Cable Wire
-
Triplex Overhead Service Drop Cable
2×6+6awg Minex Aluminum Conductor Triplex Overhead Service Drop Cable Wire
-
Triplex Overhead Service Drop Cable
Copper Conductor Triplex Service Drop Cable 600V
-
Triplex Overhead Service Drop Cable
NS75/NS90 Triplex Unjacketed Overhead Neutral Supported Cable