AAC-All Aluminum Stranded Conductor BS 215 Part1
British Standard BS 215 Part1 AAC All Aluminum Stranded Conductor
Shape of conductor: circular and sectional
Sectional area: 22 – 400mm2
Insulation: N/A
Standard: BS 215 part1
All Aluminum Stranded Conductor BS 215 Part 1 Application
AAC conductor is also called aluminium stranded conductor.This British Standard applies to aluminium stranded conductors for overhead power transmission.Aluminium wires used in the construction of the conductor is material GIE in the H9 condition as specified in BS 26273. These conductors can be used for a variety of voltages such as low, medium and high voltage. AAC is now also widely used in urban areas where short spans and high electrical conductivity are required.
STANDARD :
All Aluminum Stranded Conductor BS 215 Part 1 Standard
According to BS 215 Part 1:1970, Aluminium conductors and aluminium conductors, steel reinforced for overhead power transmission. Part 1: Aluminium stranded conductorsConstruction :
All Aluminum Stranded Conductor BS 215 Part 1 Construction
Stranded conductor
a conductor consisting of seven or more aluminium wires of the same nominal diameter twisted together in concentric layers. When the conductor consists of more than one layer, successive layers are twisted in opposite directions
Diameter
the mean of two measurements at right angles taken at the same cross section direction of lay the direction of lay is defined as right-hand or left-hand. With right-hand lay, the wires conform to the direction of the central part of the letter Z when the conductor is held vertically. With left-hand lay, the wires conform to the direction of the central part of the letter S when the conductor is held vertically
lay ratio
the ratio of the axial length of a complete turn of the helix formed by an individual wire in a stranded conductor to the external diameter of the helix For other definitions reference should be made to BS 2052).

Technical Parameter
| CODE | NOMINAL AREA | STRANDING | OVERALL DIAMETER | WEIGHT | RATED STRENGTH | ELECTRICAL RESISTANCE | CURRENT RATING* | |
|---|---|---|---|---|---|---|---|---|
| NOMINAL | TEORICAL | |||||||
| MM² | MM² | NO.×MM | MM | KG/KM | KN | Ω/KM | A | |
| Midge | 22 | 23.33 | 7/2.06 | 6.18 | 64 | 3.99 | 1.227 | 106 |
| Gnat | 25 | 26.8 | 7/2.21 | 6.6 | 73.8 | 4.83 | 1.0643 | 122 |
| Mosquito | 35 | 37 | 7/2.59 | 7.8 | 102.1 | 6.27 | 0.7749 | 141 |
| Ladybird | 40 | 42.8 | 7/2.79 | 8.4 | 117.9 | 7.28 | 0.6678 | 157 |
| Ant | 50 | 52.83 | 7/3.1 | 9.3 | 145 | 8.28 | 0.5419 | 175 |
| Fly | 60 | 63.55 | 7/3.4 | 10.2 | 174 | 9.9 | 0.4505 | 196 |
| Wasp | 100 | 106 | 7/4.39 | 13.17 | 290 | 16 | 0.2702 | 268 |
| Hornet | 150 | 157.6 | 19/3.25 | 16.25 | 434 | 25.7 | 0.1825 | 342 |
| Charfer | 200 | 213.2 | 19/3.78 | 18.9 | 587 | 35.4 | 0.1349 | 412 |
| Cockroach | 250 | 265.7 | 19/4.22 | 21.1 | 731 | 40.4 | 0.1083 | 471 |
| Butterfly | 300 | 322.7 | 19/4.65 | 23.25 | 888 | 48.75 | 0.08916 | 530 |
| Centipede | 400 | 415.2 | 37/3.78 | 26.46 | 1145 | 63.1 | 0.06944 | 616 |
| Maybug | 475 | 486,1 | 37/4,09 | 28,6 | 1342 | 74.01 | 0,05931 | 740 |
| Scorpion | 500 | 529,8 | 37/4,27 | 29,9 | 1460 | 79.98 | 0,05441 | 887 |
| Cicada | 600 | 628,3 | 37/4,65 | 32,6 | 1733 | 94.95 | 0,04588 | 1056 |
Note: *The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
YOU MAY LIKE
Related products
-
AAC-All Aluminum Conductor
All Aluminum Conductor AAC DIN 48201 Part 5
-
AAC-All Aluminum Conductor
AAC-All Aluminum Stranded Conductor AS/NZS 1531
-
AAC-All Aluminum Conductor
AAC-All Aluminum Stranded Conductor ASTM B231
-
AAC-All Aluminum Conductor
AAC-All Aluminum Stranded Conductor CSA C49
-
AAC-All Aluminum Conductor
AAC-All Aluminum Conductor IEC 61089
-
AAC-All Aluminum Conductor
AAC-All Aluminum Conductor GOST 839-80
-
AAC-All Aluminum Conductor
AAC-All Aluminum Conductor