1×2+2awg Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable

Duplex Service Drop Cable 2AWG Schnauzer #2

Code Word: Schnauzer

Size AWG (Phase Conductors): 2

Voltage: 600V

Number of cores: 2 cores

Package: Export wooden drum & iron wooden drum or as customer require

2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Application

2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable is designed for use to supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 90°C maximum.

Also Known As:
2-2 schnauzeraluminium overhead cables, 2 schnauzer overhead aluminum wire, 2 schnauzer two conductor cable, 2 schnauzer 2 conductor power cable, 2 schnauzer two conductor, 2 schnauzer aluminum drop, 2 schnauzer overhead service drop conductors, 2 schnauzer overhead service conductors.
2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Standard
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :
2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Construction
 6-6 Shepherd Aluminum Conductor Duplex Overhead Service Drop Cable


Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAAC messenger. .

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

 
TECHNICAL DATA :
2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Parameter
Code NameSchnauzer
Phas Conductor Size/AWG2
Phase Conductor Stranding7/w
Phase Conductor Insulation Thickness45 mls
Bare Neutral Messenger Size/AWG4
Bare Neutral Strand7
Bare Neutral Messenger Breaking Strength2800 Lbs
Weight Per (lb/1000 ft)XLP163.3 Lbs
Weight (lb/1000 ft) Poly156.2 Lbs
Ampacity XLP150 Amps
Ampacity Poly120 Amps
 