1×6+6awg Collie Aluminum Conductor Duplex Overhead Service Drop Cable

Duplex Service Drop Cable 6AWG Collie #6

Code Word: Collie

Size AWG (Phase Conductors): 6

Voltage: 600V

Number of cores: 2 cores

Package: Export wooden drum & iron wooden drum or as customer require

6-6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable Application

6-6 Collie Aluminum Duplex Overhead Service Drop Cable is designed for use to supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75°C maximum.

Also Known As:
6-6 collie aluminium overhead cables, 6 collie overhead aluminum wire, 6 collie two conductor cable, 6 collie 2 conductor power cable, 6 collie two conductor, 6 collie aluminum drop, 6 collie overhead service drop conductors, 6 collie overhead service conductors.

6-6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

CONSTRUCTION :
6-6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable Construction

 4-4 Terrier Aluminum Conductor Duplex Overhead Service Drop Cable

 

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAC messenger. .

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

 
TECHNICAL DATA :
6-6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

PARAMETER :
6-6 Collie Aluminum Conductor Duplex Overhead Service Drop Cable Parameter
Code NameCollie
Phas Conductor Size/AWG6
Phase Conductor Stranding7/w
Phase Conductor Insulation Thickness45 mls
Bare Neutral Messenger Size/AWG6
Bare Neutral Strand7
Bare Neutral Messenger Breaking Strength563 Lbs
Weight Per (lb/1000 ft)XLP66.8 Lbs
Weight (lb/1000 ft) Poly63.1 Lbs
Ampacity XLP85 Amps
Ampacity Poly70 Amps
Scroll to Top