2×3/0+3/0awg Mursia Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 3/0AWG Mursia #3/0

Code Word: Mursia

Size AWG (Phase Conductors): 3/0

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

3/0-3/0-3/0 Mursia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application

3/0-3/0-3/0 Mursia Aluminum Conductor Overhead Service Drop Cable Wire has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer’s premises through the weather head. It has an operational voltage rating at 600 V and the maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

Also Known As:
3/0-3/0-3/0 mursia triplex aluminum wire, 3/0-3/0-3/0 mursia triplex overhead wire, 3/0-3/0-3/0 mursia aluminum triplex, 3/0-3/0-3/0 mursia triplex conductor, 3/0-3/0-3/0 mursia overhead aluminum wire, 3/0-3/0-3/0 mursia aluminium overhead cables, 3/0-3/0-3/0 mursia overhead service drop conductor
3/0-3/0-3/0 Mursia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts

 

CONSTRUCTION :
3/0-3/0-3/0 Mursia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction 

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger)Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

TECHNICAL DATA :
3/0-3/0-3/0 Mursia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 

Technical Parameter

Code NameMursia
Phase Conductor MaterialAAC
Phase Conductor Size (awg)3/0
Phase Conductor Stranding19
Phase Conductor insulation MaterialXLPE
Phase Conductor Insulation Thickness (mils)60
Bare Neutral Messenger MaterialACSR
Bare Neutral Messenger Size(awg)1
Bare Neutral Messenger Stranding6/1
Bare Neutral Messenger Breaking Strength (Lbs)6620
Weight Per (Lbs/1000 ft) 633
Ampacity (Amps)275
Scroll to Top

Leave a message