2×4+4awg Barnacles Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 4AWG Barnacles #4

Code Word: Barnacles

Size AWG (Phase Conductors): 4

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

4-4-4 Barnacles Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application

4-4-4 Barnacles Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Primarily used for overhead service applications such as street lighting , outerdoor lighting , and temporary service for construction. To be used at votages of 600 V phase to phase or less and at conductor temperatures not to exceed 75ºC for Polyethylene insulated conductors A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

4-4-4 Barnacles Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :
4-4-4 Barnacles Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAAC messenger. 

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



 
TECHNICAL DATA :
4-4-4 Barnacles Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

Technical Parameter

Code NameBarnacles
Phase Conductor MaterialAAC
Phase Conductor Size (awg)4
Phase Conductor Stranding7
Phase Conductor insulation MaterialXLPE
Phase Conductor Insulation Thickness (mils)45
Bare Neutral Messenger MaterialAAAC
Bare Neutral Messenger Size(awg)4
Bare Neutral Messenger Stranding7
Bare Neutral Messenger Breaking Strength (Lbs)1760 
Weight Per (Lbs/1000 ft) 160
Ampacity (Amps)115 
Scroll to Top

Leave a message