2×6+6awg Minex Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Triplex Service Drop Cable 6AWG Minex #6

Code Word: Minex

Size AWG (Phase Conductors): 6

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

6-6-6 Minex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application

6-6-6 Minex Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

6-6-6 Minex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard
ASTM B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474. 
 
CONSTRUCTION :
6-6-6 Minex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAAC messenger. Optional constructions include a messenger of AAC or ACSR

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



 
TECHNICAL DATA :
6-6-6 Minex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 

Technical Parameter

Code NameMinex
Phase Conductor MaterialAAC
Phase Conductor Size (awg)6
Phase Conductor Stranding7
Phase Conductor insulation MaterialXLPE
Phase Conductor Insulation Thickness (mils)45
Bare Neutral Messenger MaterialAAAC
Bare Neutral Messenger Size(awg)6
Bare Neutral Messenger Stranding7
Bare Neutral Messenger Breaking Strength (Lbs)1110 
Weight Per (Lbs/1000 ft) 102
Ampacity (Amps)85 

 