3×3/0+3/0awg Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable
Overhead Neutral-supported Multiplex Conductor:Suffolk
Code Word: Suffolk
Size AWG (Phase Conductors): 3/0
Voltage : 600V
Number of cores: 3+1 cores
Package : Export wooden drum & iron wooden drum or as customer require
3/0-3/0-3/0-3/0 Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable Application
3/0-3/0-3/0-3/0 suffolk conductor quadruplex overhead service drop cable used to supply 3-phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors
Also Known As:
3/0-3/0-3/0-3/0 suffolk aluminum quadruplex, 3/0-3/0-3/0-3/0 suffolk overhead service drop, 3/0-3/0-3/0-3/0 suffolk three phase cable, 3/0-3/0-3/0-3/0 suffolk 3 phase cable, 3/0-3/0-3/0-3/0 suffolk 3 phase power cable, 3/0-3/0-3/0-3/0 suffolk 3 phase extension cord, 3/0-3/0-3/0-3/0 suffolk 3 phase aluminum cable, 3/0-3/0-3/0-3/0 suffolk 3 phase electrical cable, 3/0-3/0-3/0-3/0 suffolk three phase power cable, 3/0-3/0-3/0-3/0 suffolk quadruplex wire, 3/0-3/0-3/0-3/0 suffolk quadruplex overhead wire, 3/0-3/0-3/0-3/0 suffolk overhead service entrance cable.
3/0-3/0-3/0-3/0 Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable Standard
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :
3/0-3/0-3/0-3/0 Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable Construction
Phase Conductor | Strand or Compressed 1350-H19 Series Aluminum Conductor. |
Neutral(Messenger)Conductor | Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy. |
Insulation | Black Cross Linked Polyethylene (XLP) Insulation. |
TECHNICAL DATA :
3/0-3/0-3/0-3/0 Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable Technical Data
Rated voltage | kV | 0.6/1 |
Test voltage | Veff kV/Hz | 4/50 |
Laying temperature | °C | min. -5 |
Operating temperature | °C | -30 ~ +90 |
Conductor temperature | °C | max. +90 |
Short-circuit temperature | °C/s | max. +250 /5 |
Bending radius (min.) | mm | 20 × Ø of cable |
PARAMETER :
3/0-3/0-3/0-3/0 Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable Parameter
Size AWG: 3/0
Stranding: 19/w
Insulation Thickness (mils): 0.060
Neutral Size AWG: 3/0
Weight lbs./1000ft: XLP: 872
Weight lbs./1000ft: Poly: 838
Ampacity: XLP: 235
Ampacity: Poly: 180
YOU MAY LIKE
Related products
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
3×1/0+1/0awg Costena Aluminum Conductor Quadruplex Overhead Service Drop Cable (Copy)
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
3×2/0+2/0awg Grullo Aluminum Conductor Quadruplex Overhead Service Drop Cable (Copy)
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
3×3/0+3/0awg Suffolk Aluminum Conductor Quadruplex Overhead Service Drop Cable (Copy)
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
3×4/0+4/0awg Appaloosa Aluminum Conductor Quadruplex Overhead Service Drop Cable
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
3×1/0+1/0awg Shetland Aluminum Conductor Quadruplex Overhead Service Drop Cable
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
3×6+6awg Chola Aluminum Conductor Quadruplex Overhead Service Drop Cable
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
Quadruplex Cable Aluminum Conductor Overhead Service Drop Cable
-
QUADRUPLEX OVERHEAD SERVICE DROP CABLE
Quadruplex Service Drop