Aerial Insulated Cable (IEC 60502-1)

Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction.

Application
Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 1000 volts phase – to – phase or less and at conductor temperatures not to exceed 70°C for polyethylene (PE) and Polyvinyl chloride (PVC) insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

Specification
● GB/T 12527(Equivalent to IEC 60502-1)Aerial Insulated Cables for Rated Voltages up to and Including 1kV
● IEC 60228 Conductors of insulated cables 

Construction
Conductor: Conductors are stranded,circular compacted or uncompacted aluminum, copper , aluminum-alloy, ACSR etc.   
Insulation: Thermoplastic polyethylene(PE),polyvinyl chloride (PVC) ,cross-linked polyethylene (XLPE),black color,weather and UV resistant.

TypeNo. of CoresNominal size
mm²
CU/PVC, AAC/PVC, AAAC/PVC, CU/PE, AAC/PE, AAAC/PE,
CU/XLPE, AAC/XLPE, AAAC/XLPE
110 ~ 400
2,410 ~ 120
AAC/PVC, AAC/PE, AAC/XLPE3+k*10 ~ 120
*The auxiliary core k is a load-bearing core or a neutral core with a load. According to the requirements of the factory, the cross-section of the auxiliary core is optional to match the main core. (A) means steel carrying stranded wire, (B) means aluminum alloy carrying stranded wire.

                       Technical Parameter

PVC-Covered Conductors For Overhead Power Lines 
Nominal cross-sectional areaStranding and Wire DiameterApproximate Overall Diameter of Bare ConductorMaximum Resistance per kilometre at 20 °CApproximate Breaking LoadApproximate Overall Diameter of Covered ConductorApproximate Mass per kilometre of Covered Conductor
Type 8Type 16Type 8Type 16
mm²mmmmΩkNmmmmkgkg
CU/PVC
147/1.604.801.3035.7446.88.4160190
163/2.655.701.1066.5907.79.3180220
323/3.758.060.552012.7110.512.1350390
357/2.507.500.533714.0979.911.5360400
707/3.5510.650.264626.8813.514.7690750
1007/4.3012.900.181037.6415.716.99901060

PVC-Covered Conductors For Overhead Power Lines 
Nominal cross-sectional areaStranding and Wire DiameterApproximate Overall Diameter of Bare ConductorMaximum Resistance per kilometre at 20 °CApproximate Breaking LoadApproximate Overall Diameter of Covered ConductorApproximate Mass per kilometre of Covered Conductor
Type 16Type 16
mm²mmmmΩkNmmkg
COPPER-ALLOY / PVC
123/2.304.951.7807.208.2170
227/2.006.001.01112.949.6270
387/2.607.800.598321.6911.8430
757/3.7011.100.295440.2315.1810
12519/2.9014.500.178468.7518.51310
15019/3.2016.000.146582.1620.01570
                                                        Aerial Insulated Cables for Rated Voltages Up To And Including 1kV AAC/XLPE 
Number of Cores and SizeMin. No. of WiresNominal Insulation ThicknessApprox.  Diameter of CableMax. DC. Resistance at 20℃Breaking LoadApprox .
weight
mm²No.mmmmΩ/kmkNkg/km
1×1061.05.83.081.65041
1×1661.27.21.912.51765
1×2561.28.41.203.76294
1×3561.49.80.8685.177129
1×5061.410.90.6417.011166
1×70121.412.60.44310.354229
1×95151.614.80.32013.727315
1×120151.616.00.25317.339386
1×150151.818.10.20621.033476
1×185302.020.10.16426.732594
1×240302.222.80.12534.679777
1×300302.224.90.10043.349955
1×400532.227.60.077855.7071205
2×1061.011.63.081.65084
2×1661.214.41.912.517131
2×2561.216.81.203.762189
2×3561.419.60.8685.177261
2×5061.421.80.6417.011336
2×70121.425.20.44310.354463
2×95151.629.60.32013.727637
2×120151.632.00.25317.339779
4×1061.014.03.081.650167
4×1661.217.41.912.517262
4×2561.220.31.203.762378
4×3561.423.70.8685.177522
4×5061.426.40.6417.011672
4×70121.430.50.44310.354926
4×95151.635.80.32013.7271274
4×120151.638.70.25317.3391558
 
PVC-Covered Conductors For Overhead Power Lines 
Nominal cross-sectional areaStranding and Wire DiameterApproximate Overall Diameter of Bare ConductorMaximum Resistance per kilometre at 20 °CApproximate Breaking LoadApproximate Overall Diameter of Covered ConductorApproximate Mass per kilometre of Covered Conductor
Type 16Type 16
mm²mmmmΩkNmmkg
AAAC / PVC
257/2.347.021.0948.4410.6170
507/3.309.900.549816.8013.9280
1007/4.6513.950.276933.3018.0470
15019/3.4817.400.183050.6521.4680
20019/3.7618.800.156859.1022.8780
(Equ. IEC 60502-1) 
Nominal SizeMin. No. of WiresApprox.
Diameter of Conductor
Nominal
Thickness of Insulation
Max. Diameter of CableMax. DC Resistance
at 20 0C
Breaking Load
Hard copperAnnealedcopperHard copper
mm²No.mmmmmmΩ/kmΩ/kmN
1063.81.06.51.9061.833471
1664.81.28.01.1981.155486
2566.01.29.40.7490.7278465
3567.01.411.00.5400.52411731
5068.41.412.30.3990.38716052
701210.01.414.10.2760.26823461
951511.61.616.50.1990.19331759
1201813.01.618.10.1580.15339911
1501814.61.820.20.1280.12449505
1853016.22.022.50.10210.099161846
2403418.42.225.60.07770.075479823
 
Nominal SizeMin. No. of WiresApprox.
Diameter of Conductor
Nominal
Thickness of Insulation
Max. Diameter of CableMax. DC Resistance
at 20 0C
Breaking Load
AACAAACAACAAAC
mm²No.mmmmmmΩ/kmΩ/kmNN
1063.81.06.53.083.57416502514
1664.81.28.01.912.21725174022
2566.01.29.41.201.39337626284
3567.01.411.00.8681.00751778800
5068.41.412.30.6410.744701112569
701210.01.414.10.4430.5141035417596
951511.61.616.50.3200.3711372723880
1201513.01.618.10.2530.2941733930164
1501514.61.820.20.2060.2392103337706
1853016.22.022.50.1640.1902673246503
2403018.42.225.60.1250.1453467960329
3003020.82.227.20.1000.1164334975411
4005323.22.230.70.07780.090455707100548