Aerial Insulated Cable (IEC 60502-2)

Conductor: Circular compressed aluminum, aluminum-alloy, copper.

Conductor shield: Semi-conducting cross-linked polyethylene.

Insulation: Cross-linked polyethylene (Natural)

Sheath: PE & XLPE

Package : Export wooden drum & iron wooden drum or as customer require

Cable Application:

Aerial Insulated Cables with voltages of 10kV.The products primarily used for the distribution of electrical energy under normal conditions of overhead (aerial) installations.The conductors must be installed on insulators and/or spacers adequate for the service voltage. The user may want to give consideration to the dielectric compatibility of the covering, insulator, spacer etc.

Description

The conductors are stranded,circular compressed aluminum, aluminum-alloy, copper. The conductor screen is the extruded Semi-conducting conductor shield in Black. And the outer Insulation is mainly thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black with Weather or UV resistant. This standard covers both thermoplastic and cross linked polyethylene constructions, rated for 75°C or 90°C normal service temperature.

SPECIFICATION :
GB/T 14049 (Equal to IEC 60502-2) Aerial Insulated Cables For Rated Voltage of 10kV

Technical Parameter

                                                                                             10kV Aerial Insulated Cables
Nominal SizeMin. No.Approx. Diameter of ConductorMin.Nominal Thickness of InsulationNominal Thickness of Insulation ScreenMin. Breaking Load  
of WiresThickness of Conductor screen  
 (Approx.)ReducedNominalHard CopperSoft CopperHard Copper
mm²No.mmmmmmmmΩ/kmΩ/kmN 
1063.80.53.41.83 
1664.80.53.41.15 
25660.52.53.40.7490.7278465 
35670.52.53.40.540.52411731 
5068.30.52.53.40.3990.38716052 
7012100.52.53.40.2760.26823461 
951511.60.62.53.40.1990.19331759 
12018130.62.53.40.1580.15339911 
1501814.60.62.53.40.12849505 
1853016.20.62.53.40.102161846 
2403418.40.62.53.40.077779823 
3003420.60.62.53.40.061999788 
4005323.80.62.53.40.0484133040 
Nominal SizeMin. No.
of Wires
Approx. Diameter of ConductorMin.
Thickness of Conductor Screen
(Approx.)
Nominal Thickness of InsulationNominal Thickness of Insulation ScreenMin. Breaking Load
ReducedNominalAACAAACAACAAAC
mm²No.mmmmmmmmΩ/kmΩ/kmNN
1063.80.53.43.0803.574
1664.80.53.41.9102.217
2566.00.52.53.41.2001.39337626284
3567.00.52.53.40.8681.00751778800
5068.30.52.53.40.6410.744701112569
701210.00.52.53.40.4430.5141035417596
951511.60.62.53.40.3200.3711372723880
1201813.00.62.53.40.2530.2941733930164
1501814.60.62.53.40.2060.2392103337706
1853016.20.62.53.40.1640.1902673246503
2403418.40.62.53.40.1250.1453467960329
3003420.60.62.53.40.1000.1164334975411
4005323.80.62.53.40.07780.090455707100548
Size
(mm²)
No. and Dia.
of Wires
Conductor DiameterInsulation ThicknessCable DiameterRated
Strength
Weight
ALSt
No.No. /mmmmmmmmkgfkg/km
22.9 kV ACSR/AW-OC/XLPE
326/SB1/2.67.23.013.21090210
586/SB1/3.59.73.015.71900330
956/SB1/3.512.03.519.02360530
16018/SB1/3.215.44.023.43080730
24018/SB1/4.018.94.027.045001040