N2XSBY (YJV62) 8.7-15(17.5)kV (CU/XLPE/CTS/ATA/PVC)

Medium voltage cables for distribution networks, they are suitable for laying indoor, tunnel, cables trench and underground, it is able to bear external mechanical forces, but unable to bear heavy pulling force, it widely used in transformer stations, electric power plants and industrial plants.

Application

Gongniu Cable’s N2XSBY (CU/XLPE/STA/PVC) Power Cables are designed for use in power distribution networks. These versatile cables are suitable for various installation environments. You can install them indoors, within tunnels, in cable trenches, or lay them directly underground. They are widely used in transformer stations, electric power plants, and different industrial plants. While the N2XSBY cable can withstand external mechanical forces, it is not designed to bear heavy pulling tension.

Description

The N2XSBY cable from Gongniu Cable is built with quality components for reliable and safe operation.

  • Conductor: The cable features a Class 2 circular compacted copper conductor.
  • Conductor Screen: A non-metallic, semi-conducting compound is used for the conductor screen.
  • Insulation: We use Cross-Linked Polyethylene (XLPE) for its excellent insulating properties.
  • Insulation Screen: A non-metallic, semi-conducting compound also serves as the insulation screen.
  • Metallic Screen: A copper tape acts as the metallic screen.
  • Inner Sheath: The inner sheath is made of Polyvinyl Chloride (PVC).
  • Armour: For added protection, the cable is armored with non-magnetic steel tape.
  • Outer Sheath: A robust Polyvinyl Chloride (PVC) outer sheath encases the cable.

This Gongniu Cable product offers good electrical and mechanical properties. Key characteristics include minimal dielectric loss and high insulation resistance. Furthermore, the PVC outer sheath provides adequate resistance to grease, oil, and abrasion, ensuring durability in various conditions.

Specification

Our N2XSBY cables are manufactured in compliance with recognized international standards.

  • The conductors meet the requirements of IEC 60228 (Conductors of Insulated Cables).
  • The overall cable construction adheres to IEC 60502-2 (Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) – Part 2: Cables for Rated Voltages of 6kV(Um=7.2kV) and 30kV(Um=36kV)).

 

 

 

N2XSBY/NA2XSBY (YJV62/YJLV62) 8.7-15(17.5)kV IEC 60502-2

No. of Cores and Nominal Cross Section (mm²) Nominal Insulation Thickness (mm) Nominal Steel Tape Thickness (mm) Nominal Sheath Thickness (mm) Approx. Overall Diameter (mm) Approx. Weight (kg/km) Max. DC Resistance of Conductor at 20℃ (Ω/km)
Cu Al Cu Al
1×25 4.5 0.20 1.7 24.8 951 798 0.727 1.20
1×35 4.5 0.20 1.8 26.0 1090 879 0.524 0.868
1×50 4.5 0.20 1.8 27.1 1245 959 0.387 0.641
1×70 4.5 0.20 1.9 29.0 1516 1102 0.268 0.443
1×95 4.5 0.20 1.9 30.8 1825 1251 0.193 0.320
1×120 4.5 0.20 2.0 32.2 2108 1382 0.153 0.253
1×150 4.5 0.20 2.0 33.7 2417 1520 0.124 0.206
1×185 4.5 0.50 2.1 36.8 3183 2053 0.0991 0.164
1×240 4.5 0.50 2.2 39.3 3819 2352 0.0754 0.125
1×300 4.5 0.50 2.3 41.7 4497 2658 0.0601 0.100
1×400 4.5 0.50 2.4 44.8 5448 3079 0.0470 0.0778
1×500 4.5 0.50 2.5 48.6 6623 3616 0.0366 0.0605
1×630 4.5 0.50 2.6 52.5 8142 4237 0.0283 0.0469