NA2XSY (YJLV) 6-10(12)kV (AL/XLPE/CTS/PVC)

Medium voltage cables for distribution networks. They are suitable for laying Indoor, tunnel, cable trench, shaft or buried laying, The cable can withstand mechanical external forces and a certain tensile force, it widely used in transformer stations, electric power plants and industrial plants.IEC60502-2

Application

Our NA2XSY – YJLV cable is designed for medium voltage distribution networks. You can install this versatile cable in various settings. It is suitable for indoor use, in tunnels, and in cable trenches. You can also lay it directly in shafts or bury it underground. This cable is ideal for transformer stations and power plants. Industrial plants also benefit from its use. The cable is built to withstand mechanical pressures and certain pulling forces during installation and service.

Description

The NA2XSY – YJLV cable from Gongniu Cable features a robust construction for dependable performance.

  • Conductor: The cable uses circular compacted aluminum conductors (Class 2). This ensures efficient electrical transmission.
  • Insulation: Cross-Linked Polyethylene (XLPE) provides the main insulation. XLPE offers excellent electrical properties and can handle high temperatures.
  • Screening System:
    • A non-metallic, semi-conducting compound serves as the conductor screen.
    • Another non-metallic, semi-conducting compound acts as the insulation screen.
    • A Copper Tape Screen (CTS) provides the metallic screen. This system helps maintain a uniform electric field and enhances safety.
  • Outer Sheath: A tough Polyvinyl Chloride (PVC) outer sheath protects the cable. This sheath offers good resistance to grease, oil, and abrasion. It also provides mechanical protection.

This cable offers good electrical and mechanical properties. It features minimal dielectric loss and high insulation resistance.

Specification

  • Standards: This cable meets international standards for quality and performance.
    • IEC 60228: For the conductors of insulated cables.
    • IEC 60502-2: For power cables with extruded insulation for rated voltages from 1kV (UmU_m=1.2kV) up to 30kV (UmU_m=36kV).
  • Voltage Rating: Suitable for medium voltage networks as specified in IEC 60502-2.
  • Construction Elements: Aluminum / XLPE Insulation / Copper Tape Screen / PVC Sheath.

 

 

NA2XSY (YJLV) 6-10(12)kV IEC 60502-2

No. of Cores and Nominal Cross Section (mm²) Min. Number of Wires Nominal Insulation Thickness (mm) Nominal Copper Tape Thickness (mm) Nominal Steel Tape Thickness (mm) Nominal Sheath Thickness (mm) Approx. Overall Diameter (mm) Approx. Weight (kg/km) Max. DC Resistance of Conductor at 20℃ (Ω/km)
No.
3X25 6 3.4 0.10 2.5 2.5 47.4 3631 1.20
3X35 6 3.4 0.10 2.5 2.6 49.8 3921 0.868
3X50 6 3.4 0.10 2.5 2.7 52.5 4305 0.641
3X70 12 3.4 0.10 2.5 2.8 56.6 4909 0.443
3X95 15 3.4 0.10 2.5 2.9 60.7 5554 0.320
3X120 15 3.4 0.10 2.5 3.0 63.7 6084 0.253
3X150 15 3.4 0.10 2.5 3.1 67.1 6702 0.206
3X185 30 3.4 0.10 2.5 3.2 71.2 7499 0.164
3X240 30 3.4 0.10 3.15 3.5 78.3 9503 0.125
3X300 30 3.4 0.10 3.15 3.6 83.4 10661 0.100
3X400 53 3.4 0.10 3.15 3.9 90.1 12308 0.0778
3X500 53 3.4 0.10 3.15 4.1 98.1 14303 0.0605
3X630 53 3.4 0.10 3.15 4.3 106.9 16596 0.0469
Scroll to Top

Leave a message