XLPE Insulated 3+2 Cores Copper Cable 3X4+2X2.5mm2
XLPE Insulated, PVC Sheathed Unarmoured 3+2 Cores Copper Cable 3X4+2X2.5mm2, 0.6/1kV
Number of Cores: 3+2
Cross section area: 3X4+2X2.5mm2
Conductor: Copper
Voltage: 0.6/1kV
Package : Export wooden drum & iron wooden drum or as customer require
XLPE 3X4+2X2.5mm2 Copper Cable Application
XLPE insulated 3+2 cores power cables are normally used in power transmission and distribution systems. The 3+2 cores XLPE cable is referred to as IEC60502 CU/XLPE/PVC 0.6/1KV.These cables are used for outdoor and indoor installations in damp and wet applications. They are normally used for power distribution in urban networks, industrial plants and energy distribution. For mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage. Suitable where space is at a premium.
STANDARDS :
XLPE 3X4+2X2.5mm2 Copper Cable Standards:
IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) – Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)
CONSTRUCTION :
XLPE 3X4+2X2.5mm2 Copper Cable Construction
1. Conductor: Copper , Class 1: solid conductor, or Class 2: stranded conductor2. Insulation: Cross-linked polyethylene XLPE
3. Filler: Non-hygroscopic material
4. Binder tape: Non-hygroscopic material
5. Outer sheath: Polyvinyl chloride PVC

| Cable Type: | CU/XLPE/PVC |
| Operating voltage, U0 / U (V): | 600/1000 |
| Number of cores: | 3+2 |
| Phase Conductor Nominal Area (mm2): | 4 |
| Earth Conductor Nominal Area (mm2): | 2.5 |
| Phase Conductor Stranding: | 1 or 7 |
| Earth Conductor Stranding: | 1 or 7 |
| Phase Conductor Insulation Thickness (mm): | 0.7 |
| Earth Conductor Insulation Thickness (mm): | 0.7 |
| Sheath Thickness (mm): | 1.8 |
| Cable Overall Diameter (O.D.) (mm): | 14.3 |
| Cable Weight Per 1000 Meters (kg): | 260 |
| Phase Conductor Resistance DC 20°C Per 1000 Meters (Ω): | 4.61 |
| Earth Conductor Resistance DC 20°C Per 1000 Meters (Ω): | 7.41 |
| Allowable Ampacity in Air (Amps): | 37 |
| Allowable Ampacity in Ground (Amps): | 51 |
| Test Voltage: | 3.5kV for 5 minutes |
| Operating temperature (°C) : | -15 to +90 |
| Final short circuit temperature (°C): | 250 |
YOU MAY LIKE
Related products
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X240+2X120mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X150+2X70mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X120+2X70mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X95+2X50mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X70+2X35mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X50+2X25mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
XLPE Insulated 3+2 Cores Copper Cable 3X2.5+2X1.5mm2
-
3+2 Cores Copper Cable CU/XLPE/PVC
0.6/1kV 3+2 Cores XLPE Insulated PVC Sheathed Copper Cable Unarmoured